Occupant load calculator for warehouses.
The IBC and IFC Table 1004.5 calculator preset to the function of space a warehouse is counted under. Change the edition or the function, enter the area, and the occupant load updates as you type. Provided by FireInspection360, the fire prevention platform built by fire inspectors.

Calculate an occupant load
Load factors are from IBC / IFC Table 1004.5 for the edition you pick. Business areas changed from 100 to 150 gross square feet per occupant in the 2018 edition, so the edition changes the answer.
How a warehouse is counted.
Warehouses are the lowest-density function in the table at 500 gross square feet per person. The office inside a warehouse is business space and the shipping dock is counted with the warehouse. The load is small, but the exits still have to meet the travel distance limits for a Group S occupancy, which is where a large warehouse usually runs into trouble.
- The office area inside the warehouse is a separate business function.
- Travel distance to an exit, not the occupant load, is usually the governing egress question in a warehouse.
- High-piled storage over 12 feet brings IFC Chapter 32 into play regardless of the load.
Not every space in a warehouse shares one factor: change the function of space above for each area and add the loads together. Related: the egress requirements calculator reads what the total requires.
The calculator preset for restaurants, bars and nightclubs, churches, gyms and fitness studios, classrooms, offices, retail stores, warehouses, day care centers, conference rooms.
Occupant load is where every life safety decision starts.
The International Fire Code and the International Building Code make the occupant load the first number in every life safety decision inside a structure. Under IFC Section 1004 it is the floor area of the space, gross or net depending on how the space is used, divided by a load factor in square feet per occupant. Those load factors are not suggestions. They set the maximum number of people permitted in a space at any one time, and a mercantile sales floor, a standing-room assembly space and a commercial kitchen each get their own factor because the exit demand and the egress pattern differ. For a fire marshal, knowing whether a gross or a net area applies to each function of space is the first step toward catching a violation before it happens.
Occupant load and egress capacity are related but distinct, and the distinction matters on an inspection. The occupant load says how many people may occupy the space. Egress capacity, under IFC Section 1005 and IBC Chapter 10, says how many people the exits can discharge in an emergency: door widths, travel distances, stair capacity and exit access corridors all have to be sized for the posted load. When the two fall out of step the result is a life safety violation for the business, the owner and the authority having jurisdiction alike. Re-checking the posted occupant load placard and the egress paths on every inspection is part of the job.
Compliance goes further than a number on a placard. A prevention bureau working a community risk reduction strategy needs the occupant load to live in the property record beside the current tenant, the last inspection and any open violation for overcrowding or blocked egress. A tenant that turns a storage area into an assembly space changes the classification, the load factor and often the whole egress design, and rarely tells the bureau. Tracking that in the record, not in a spreadsheet, is what keeps a certificate of occupancy honest.
How FireInspection360 keeps occupancies current between inspections
FireInspection360 is fire prevention software built for the code enforcement side of the house, not dispatch and not incident reporting. Every property carries one record: permits, inspection history, violations with photos, ITM reports and pre-incident plans in one place, with recurring inspections that put each occupancy back in front of an inspector on schedule. When a permit for a tenant improvement or a change of use comes in, it lands on the same record the inspector opens in the field.